Le CORUM / L'AUDITORIUM BERLIOZ, Montpellier / France



Le CORUM / L´AUDITORIUM BERLIOZ, Montpellier / France
General Arrangement Drawing
View at site
Concert hall
Le CORUM / L´AUDITORIUM BERLIOZ, Montpellier / France
Project
Le Corum / l’Auditorium Berlioz
Montpellier
Design load
230.000 kN
   
Building
Centre for Opera, Concert, Congress, etc., 2000 seats
Arrangement of spring elements
Supporting the auditorium including the orchestra pit and stage
   
Structure
Isolated auditorium within the main structure
Vibration Control effect
Insertion Loss 20 dB (measured)
   
Noise and vibration source
Nearby railway track
Completion
1990
   
Base isolation system
Fully-prestressable GERB spring elements, Type GP + GPV
Vertical system natural frequency 4,0 Hz
Client
Ville de Montpellier